Turbo ventilators are designed and engineered to exhaust Industrial pollutants such as smoke, dust, poisonous gases, humidity, fumes, heat and many more invisible irritants from the covered area. Turbine Ventilator provides a safe, cool, healthier and more controlled environment by removing the entrapped heat and industrial emission ensuring the health of workers, thus contributing to an increase in workers productivity. Turbo Ventilators provide energy free cooling and fresh air through out the year.

This product is a Wind operated Turbo ventilators installed on the roof and is rotated by the Wind, the stale air inside is exhausted through the vanes and a natural inward flow of fresh air is boosted.Turbine Air Turbo ventilators works without electricity, it runs on wind velocity and it works 24 hours a day and 365 days a year This Turbo ventilators system functions and performs with the unlimited energy source like wind energy thus saving running cost exhaust fans, wiring, maintenance etc.

Wind turbo ventilators does not require operating time, it continuously rotate with the wind , removes moisture laden air in the winter and extremely hot air in the summer.

  1. Advantage
  2. Available Sizes
  3. Technical Specification
  4. Application

Highly Affordable

Suitable for all kinds of building and explosive environment

24hrs ventilation is assured

Easy installation

Efficient even without fast blowing wind

Minimum maintenance and operation cost

Available Size 24 20 16
Available Make Aluminium / Stainless Steel Aluminium / Stainless Steel Aluminium / Stainless Steel
Available Base Aluminium / FRP Aluminium / FRP Aluminium / FRP
The wind influences the performance of the ventilator in two ways

As the Wind approaches and strikes the ventilator, it jumps, creating an area of low pressure on the leeward side of the turbine, causing a continuous extraction of air from the building end

As the turbine rotates, the centripetal forces associated with the rotation fling air outwards form the tips of the vanes. Replacement air is drawn into the throat of the ventilator from the building causing continuous ventilation.

Type of building Air changes per Hour
Ware Houses 3-5
Factotries and workshops 3-8
Assembly Halls 6-12
Garages 6-12
Toilets 7-12
Laundries 7-15
Poultrey Houses 7-25
Factotries|(Heavy) 20-40

The Ventilating Times of the Different

Type of building Time/Hour Building Time/hr
Machinery 4-15 Textile 3-7
Forming 10-30 Dyeing 10-40
Foundry 10-30 Repairing 10-2 0
Electroplate 12-20 Washing 10-30
Drying 10-20 Boiler 15-30
Food 3-8 Lab 6-15
Wood 3-8 Pump 5-10
Paper 8-15
Building Time/Hour Building Time/hr
Library 6-10 Receptionroom 4-12
Church 6-10 Toilet 5-10
Classroom 3-8 WC 4-14
Storehouse 3-6 Smokking room 5-15
Carport 4-10 Restarunt 6-12
Sickroom 2-4 House room 5-10
Kitchen 7-15 Office 2-5
Restroom 10 Sterillizedroom 8-15

The Ventilating Cube of Metal TG-600

wind Speed(KM) 3.2 6.4 8
Model Turbine Diameter(MM) Total Diameter(MM) Room Height(M) the vendilating cube per hour(M3)
Tempertature Difference 5 10 15 5 10 15 5 10 15
TG-600 720 600 3 1528 1716 1930 2076 2186 2314 2327 2510 2700
6 1712 1817 1986 2150 2360 2694 2766 2895 2895
9 1913 2190 2630 2659 3065 2956 3105 3348 3348
12 2065 2345 2700 2864 2925 3148 3188 3346 3468
wind Speed(KM) 9.6 612.8 16.0
Tempertature Difference 5 10 15 5 10 15 5 10 15
Model Turbine Diameter(MM) Total Diameter(MM) Room Height(M) the vendilating cube per hour(M3)
TG-600 720 600 3 2720 2975 3070 3358 3565 3760 4033 4240 4357
6 2921 3158 3330 3547 3785 3961 4188 4430 4610
9 3150 3350 3535 3875 4161 4270 4518 4882 5050
12 3380 3786 3942 4215 4410 4656 4821 5125 5230

Turbo ventilators-Application

Turbo ventilators used in Industries.

Turbo ventilators used in Godowns and warehouses.

Turbo ventilators used in Theaters and Community halls.

Hospitals and schools.

Factories.

Auditoriums.

Power houses and lift rooms.

  1. Advantage
  2. Available Sizes
  3. Technical Specification
  4. Application

Highly Affordable

Suitable for all kinds of building and explosive environment

24hrs ventilation is assured

Easy installation

Efficient even without fast blowing wind

Minimum maintenance and operation cost

Available Size 24 20 16
Available Make Aluminium / Stainless Steel Aluminium / Stainless Steel Aluminium / Stainless Steel
Available Base Aluminium / FRP Aluminium / FRP Aluminium / FRP
The wind influences the performance of the ventilator in two ways

As the Wind approaches and strikes the ventilator, it jumps, creating an area of low pressure on the leeward side of the turbine, causing a continuous extraction of air from the building end

As the turbine rotates, the centripetal forces associated with the rotation fling air outwards form the tips of the vanes. Replacement air is drawn into the throat of the ventilator from the building causing continuous ventilation.

Type of building Air changes per Hour
Ware Houses 3-5
Factotries and workshops 3-8
Assembly Halls 6-12
Garages 6-12
Toilets 7-12
Laundries 7-15
Poultrey Houses 7-25
Factotries|(Heavy) 20-40

The Ventilating Times of the Different

Type of building Time/Hour Building Time/hr
Machinery 4-15 Textile 3-7
Forming 10-30 Dyeing 10-40
Foundry 10-30 Repairing 10-2 0
Electroplate 12-20 Washing 10-30
Drying 10-20 Boiler 15-30
Food 3-8 Lab 6-15
Wood 3-8 Pump 5-10
Paper 8-15
Building Time/Hour Building Time/hr
Library 6-10 Receptionroom 4-12
Church 6-10 Toilet 5-10
Classroom 3-8 WC 4-14
Storehouse 3-6 Smokking room 5-15
Carport 4-10 Restarunt 6-12
Sickroom 2-4 House room 5-10
Kitchen 7-15 Office 2-5
Restroom 10 Sterillizedroom 8-15

The Ventilating Cube of Metal TG-600

wind Speed(KM) 3.2 6.4 8
Model Turbine Diameter(MM) Total Diameter(MM) Room Height(M) the vendilating cube per hour(M3)
Tempertature Difference 5 10 15 5 10 15 5 10 15
TG-600 720 600 3 1528 1716 1930 2076 2186 2314 2327 2510 2700
6 1712 1817 1986 2150 2360 2694 2766 2895 2895
9 1913 2190 2630 2659 3065 2956 3105 3348 3348
12 2065 2345 2700 2864 2925 3148 3188 3346 3468
wind Speed(KM) 9.6 612.8 16.0
Tempertature Difference 5 10 15 5 10 15 5 10 15
Model Turbine Diameter(MM) Total Diameter(MM) Room Height(M) the vendilating cube per hour(M3)
TG-600 720 600 3 2720 2975 3070 3358 3565 3760 4033 4240 4357
6 2921 3158 3330 3547 3785 3961 4188 4430 4610
9 3150 3350 3535 3875 4161 4270 4518 4882 5050
12 3380 3786 3942 4215 4410 4656 4821 5125 5230
The wind influences the performance of the ventilator in two ways

As the Wind approaches and strikes the ventilator, it jumps, creating an area of low pressure on the leeward side of the turbine, causing a continuous extraction of air from the building end

As the turbine rotates, the centripetal forces associated with the rotation fling air outwards form the tips of the vanes. Replacement air is drawn into the throat of the ventilator from the building causing continuous ventilation.

Type of building Air changes per Hour
Ware Houses 3-5
Factotries and workshops 3-8
Assembly Halls 6-12
Garages 6-12
Toilets 7-12
Laundries 7-15
Poultrey Houses 7-25
Factotries|(Heavy) 20-40

The Ventilating Times of the Different

Type of building Time/Hour Building Time/hr
Machinery 4-15 Textile 3-7
Forming 10-30 Dyeing 10-40
Foundry 10-30 Repairing 10-2 0
Electroplate 12-20 Washing 10-30
Drying 10-20 Boiler 15-30
Food 3-8 Lab 6-15
Wood 3-8 Pump 5-10
Paper 8-15
Building Time/Hour Building Time/hr
Library 6-10 Receptionroom 4-12
Church 6-10 Toilet 5-10
Classroom 3-8 WC 4-14
Storehouse 3-6 Smokking room 5-15
Carport 4-10 Restarunt 6-12
Sickroom 2-4 House room 5-10
Kitchen 7-15 Office 2-5
Restroom 10 Sterillizedroom 8-15

The Ventilating Cube of Metal TG-600

wind Speed(KM) 3.2 6.4 8
Model Turbine Diameter(MM) Total Diameter(MM) Room Height(M) the vendilating cube per hour(M3)
Tempertature Difference 5 10 15 5 10 15 5 10 15
TG-600 720 600 3 1528 1716 1930 2076 2186 2314 2327 2510 2700
6 1712 1817 1986 2150 2360 2694 2766 2895 2895
9 1913 2190 2630 2659 3065 2956 3105 3348 3348
12 2065 2345 2700 2864 2925 3148 3188 3346 3468
wind Speed(KM) 9.6 612.8 16.0
Tempertature Difference 5 10 15 5 10 15 5 10 15
Model Turbine Diameter(MM) Total Diameter(MM) Room Height(M) the vendilating cube per hour(M3)
TG-600 720 600 3 2720 2975 3070 3358 3565 3760 4033 4240 4357
6 2921 3158 3330 3547 3785 3961 4188 4430 4610
9 3150 3350 3535 3875 4161 4270 4518 4882 5050
12 3380 3786 3942 4215 4410 4656 4821 5125 5230

Turbo ventilators-Application

Turbo ventilators used in Industries.

Turbo ventilators used in Godowns and warehouses.

Turbo ventilators used in Theaters and Community halls.

Hospitals and schools.

Factories.

Auditoriums.

Power houses and lift rooms.

Louver

We enjoy assembling of Louver with mechanical standard. Louvers can improve a building structural look and meet ventilation air development prerequisites. ALFA louvers are widely utilized as a part of ventilation arrangements we are putting forth our customers brilliant scope of color covered/non shaded Louvers. louvers intended for both outside air admission and fumes air applications. These are made utilizing fantastic crude of material.

  1. Features
  2. Specification

Long life

Accurate dimension

Perfect finish

1)FACTORY MADE/PPGI

2)75 MM WIDE LOUVERS

3)BLADES-0.5 MM TCT

4)C SUPPORT-1 MM PPGI

5)ALUMINIUM REVITED

  1. Features
  2. Specification

Long life

Accurate dimension

Perfect finish

1)FACTORY MADE/PPGI

2)75 MM WIDE LOUVERS

3)BLADES-0.5 MM TCT

4)C SUPPORT-1 MM PPGI

5)ALUMINIUM REVITED

Ridge Ventilators

Owing to a modernized infrastructure for trouble-free processing & post-production, we are instrumental in offering Ridge Ventilators. Our offered ventilator is highly demanded in the market due to its excellent finish & better ventilation. This ventilator is designed using quality assured material as per the set industry norms. Customers can avail this ventilator from us at competitive rates.

  1. Features
  2. Specification

Features

Available in standard sizes as well as in customized ranges.

Efficient design and workability in different weather conditions.

Longer service life.

Generates good air system.

Specification

A)300 MM THROTH

1)MS STRUCTURE POLYSTER PAINTED

2)TOP SKIN-PPGI 0.5 MM TCT

3)MESH -SS 25*25 BIRD MESH

4)OVERALL GIRTH-520 MM

B)600 MM THROTH

1)MS STRUCTURE POLYSTER PAINTED

2)TOP SKIN-PPGI 0.5 MM TCT

3)MESH -SS 25*25 BIRD MESH

4)OVERALL GIRTH-886 MM

C)600 MM THROTH

1)FABRICATED STEEL TEBE FRAME WITH POLYSTER PAINTED

2)TOP SKIN-PPGI 0.5 MM TCT

3)MESH -SS 25*25 BIRD MESH

  • ANY LENGTHCONTINUES OR GAPS
  • FIXINNG AT SITE
  • MINIMUM ORDER QUANTITY 100 MTR
  1. Features
  2. Specification

Features

Perfect thickness

Light weight

Accurate dimens

Specification

A)300 MM THROTH

1)MS STRUCTURE POLYSTER PAINTED

2)TOP SKIN-PPGI 0.5 MM TCT

3)MESH -SS 25*25 BIRD MESH

4)OVERALL GIRTH-520 MM

B)600 MM THROTH

1)MS STRUCTURE POLYSTER PAINTED

2)TOP SKIN-PPGI 0.5 MM TCT

3)MESH -SS 25*25 BIRD MESH

4)OVERALL GIRTH-886 MM

C)600 MM THROTH

1)FABRICATED STEEL TEBE FRAME WITH POLYSTER PAINTED

2)TOP SKIN-PPGI 0.5 MM TCT

3)MESH -SS 25*25 BIRD MESH

  • ANY LENGTHCONTINUES OR GAPS
  • FIXINNG AT SITE
  • MINIMUM ORDER QUANTITY 100 MTR

Polycarbonate Sheet

We are among the leading names involved in wholeselling and distributing the finest quality of the Lexan Corrugated Profile Sheet to match various metal profiles available in the market JSW, Kirby, Llyods, Bhushan Steel, TATA Blue Scope Etc..

Polycarbonate sheets are environment friendly green global product. Strip lights can be combined into any architectural structure. Its can be used in all buildings to ensure uniform lighting. Light transmission is 40% to 72% in embossed and 40% to 90% in solid compact sheet.

Custom shaped Strip Lights-

Alfa – Lexan brand Strip lights can be adapted to individual construction needs. Strip lights can be produced in flexible widths, as well as endless length.

Application– Skylights & Wall Lights

Sizes –Custom sizes upto 6mtr

Thickness – Embossed & Compact

Colour – Clear & Bronze

Reflective Thermal Insulation

Alfa Cell insulation offers industrial sheds owners an extremely durable & high performance insulation medium that resists rodents, insects etc. and can be washed as required. The fibre free and thermo reflective construction of our product is made to resist tearing. It also replaces fibre based insulation blanket in all agricultural and industrial shed applications where it is installed quickly and often without the use of product support mesh.

Alfacel insulation is highly effective and extremely easy to install replacing fibre based insulation in poultry. Our range is incomparable to other agricultural shed application where its performance, durability and waterproof qualities make it unchallenged by conventional insulation medium.

Roofing Accessories